Remington Chainsaw Manual Oiler Not Working
As a chainsaw owner, there’s nothing more frustrating than having your saw not work properly. One of the most common problems that can occur is a manual oiler that isn’t working. This can be a major inconvenience, as it can lead to your saw overheating and becoming damaged. In this guide, I will walk you through the steps to troubleshoot and fix a Remington chainsaw manual oiler that isn’t working. By following these steps, you can quickly diagnose and resolve the problem, and get your saw back up and running in no time.
Most Common Reasons Of Remington Chainsaw Manual Oiler Not Working
Most Common Reasons Of Remington Chainsaw Manual Oiler Not Working
1. Oiler Hose Clogged
The most common reason for a Remington chainsaw manual oiler not working is a clogged oiler hose. This can happen if the hose becomes kinked or pinched, or if sawdust or other debris builds up inside the hose. To fix this problem, you will need to clean or replace the oiler hose.
2. Oiler Pump Not Working
Another common cause of a Remington chainsaw manual oiler not working is a faulty oiler pump. The oiler pump is responsible for pumping oil from the reservoir to the chain. If the pump is not working properly, it will not be able to deliver oil to the chain, and the chain will become dry and overheat. To fix this problem, you will need to replace the oiler pump.
3. Oiler Reservoir Empty
A third common cause of a Remington chainsaw manual oiler not working is an empty oiler reservoir. If the oiler reservoir is empty, the oiler pump will not be able to pump any oil to the chain. To fix this problem, you will need to refill the oiler reservoir.
4. Oiler Valve Stuck
The oiler valve is responsible for controlling the flow of oil from the reservoir to the chain. If the oiler valve is stuck open or closed, it will not be able to properly regulate the flow of oil, and the chain may become dry or over-oiled. To fix this problem, you will need to clean or replace the oiler valve.
5. Oiler O-Ring Damaged
The oiler O-ring is a small rubber ring that seals the oiler pump to the reservoir. If the O-ring is damaged, it will allow oil to leak out of the pump, and the chain may become dry. To fix this problem, you will need to replace the oiler O-ring.
How to Troubleshoot: Remington Chainsaw Manual Oiler Not Working
Symptoms of a Chainsaw Manual Oiler Not Working
There are a few signs that can indicate that your chainsaw’s manual oiler is not working properly. These include:
The chain is not being lubricated properly, which can lead to overheating and damage to the chain and bar.
The oil reservoir is empty, even though you have been adding oil regularly.
The oiler is making a strange noise or is not working at all.
Troubleshooting a Chainsaw Manual Oiler
If you suspect that your chainsaw’s manual oiler is not working properly, you can try the following troubleshooting steps:
1. Check the oil level. The first thing you should do is check the oil level in the reservoir. If the reservoir is empty, fill it up with the appropriate type of oil.
2. Check the oil line. The oil line runs from the reservoir to the bar and chain. Make sure that the line is not kinked or blocked. If it is, straighten it out or clear the blockage.
3. Check the oiler pump. The oiler pump is responsible for pumping oil from the reservoir to the bar and chain. If the pump is not working properly, it will not be able to lubricate the chain properly. You can check the pump by turning the chainsaw on and observing the oil line. If the oil is not flowing properly, the pump may need to be replaced.
4. Check the oil filter. The oil filter helps to keep dirt and debris from entering the oil reservoir. If the filter is clogged, it will restrict the flow of oil to the bar and chain. You can check the filter by removing it from the reservoir and inspecting it for dirt and debris. If the filter is clogged, it should be replaced.
Preventative Maintenance
The best way to avoid problems with your chainsaw’s manual oiler is to perform regular preventative maintenance. This includes:
Checking the oil level regularly and adding oil as needed.
Cleaning the oil line and oil filter regularly.
Inspecting the oiler pump for damage or wear.
By following these simple steps, you can help to ensure that your chainsaw’s manual oiler is working properly and that your chainsaw is properly lubricated.
Contact a Chainsaw Repair Professional
If you have tried troubleshooting the problem yourself and you are still having problems, it is best to contact a chainsaw repair professional. A qualified technician will be able to diagnose the problem and make the necessary repairs.
FAQs: Remington Chainsaw Manual Oiler Not Working
Why is my Remington chainsaw manual oiler not working?
There are a few possible reasons why your Remington chainsaw manual oiler may not be working. Here are some of the most common causes:
The oiler is not plugged in properly. Make sure that the oiler is plugged into an outlet that is working and that the plug is securely inserted into the outlet.
The oiler is not turned on. Check to make sure that the oiler is turned on. The switch is usually located on the side of the oiler.
The oiler is clogged. The oiler may be clogged with dirt or debris, which can prevent the oil from flowing properly. To clean the oiler, remove the oil reservoir and clean it with a soft cloth.
The oiler is not the correct size for your chainsaw. Make sure that the oiler is the correct size for your chainsaw. The oiler should be able to hold enough oil to lubricate the chainsaw for the length of time that you plan to use it.
How do I fix my Remington chainsaw manual oiler?
If your Remington chainsaw manual oiler is not working, you can try the following steps to fix it:
1. Check the oiler is plugged in properly and turned on.
2. Clean the oiler if it is clogged.
3. Replace the oiler if it is the incorrect size.
If you are unable to fix the oiler yourself, you can take it to a qualified service technician for repair.
What type of oil should I use in my Remington chainsaw manual oiler?
You should use a high-quality chainsaw oil in your Remington chainsaw manual oiler. The oil should be SAE 30 or SAE 10W-30.
How often should I oil my Remington chainsaw?
You should oil your Remington chainsaw every time you use it. If you are using your chainsaw for a long period of time, you may need to oil it more frequently.
What should I do if my Remington chainsaw runs out of oil?
If your Remington chainsaw runs out of oil, you should stop using the chainsaw immediately and add more oil to the oil reservoir. If you continue to use the chainsaw without oil, you could damage the engine.
Next Post You May Like: Remington Chainsaw Oiler Not Working